-- REDSTONE-RXSYS-MIB
--
-- Redstone Communications Inc. Enterprise MIB
-- RX1400/RX700 System MIB
--
-- Copyright 1998-1999 Redstone Communications, Incorporated.
-- Copyright 2000 Unisphere Solutions, Inc.
-- All Rights Reserved.
-- *****************************************************************REDSTONE-RXSYS-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPE,Integer32,Unsigned32,TimeTicksFROM SNMPv2-SMI
TEXTUAL-CONVENTION,DisplayString,TruthValue,DateAndTimeFROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUP,NOTIFICATION-GROUPFROM SNMPv2-CONF
InterfaceIndexOrZeroFROM IF-MIB
rsMgmt
FROM REDSTONE-SMI
RsEnable
FROM REDSTONE-TC;rsRXSysMIB MODULE-IDENTITYLAST-UPDATED"200004251844Z"-- 2000-Apr-25 2:44pm EDTORGANIZATION"Redstone Communications, Inc."CONTACT-INFO"Redstone Communications, Inc.
5 Carlisle Road
Westford MA 01886
USA
+1-978-692-1999
mib@redstonecom.com"DESCRIPTION"Added oc3oc12Pos/oc3oc12Atm card types."REVISION"200005090000Z"DESCRIPTION"MIB objects for managing RX1400/RX700 systems."REVISION"200004251844Z"-- 2000-Apr-25 2:44pm EDTDESCRIPTION"Added board serial number, assembly number and assembly revision."REVISION"200001200000Z"DESCRIPTION"Added OC-12 card and Dual FE card support."REVISION"200001180000Z"DESCRIPTION"Added redundancy/reversion and boot record configuration support."REVISION"9912100000Z"DESCRIPTION"Added 'ct1' enumeration to RsSysCardType and rsRxSysPortType."REVISION"9907020000Z"DESCRIPTION"Added 'ce1' enumeration to RsSysCardType and rsRxSysPortType."REVISION"9904220000Z"DESCRIPTION"Added new enumerations to RsSysCardType and rsRxSysPortType."REVISION"9801010000Z"DESCRIPTION"Initial version of this MIB module."::={ rsMgmt 17}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- MIB Structure
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysTrap OBJECTIDENTIFIER::={ rsRXSysMIB 0}rsRXSysObjects OBJECTIDENTIFIER::={ rsRXSysMIB 1}rsRXSysConformance OBJECTIDENTIFIER::={ rsRXSysMIB 2}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++--
-- Object Groups
--rsRXSysGeneral OBJECTIDENTIFIER::={ rsRXSysObjects 1}rsRXSysFabric OBJECTIDENTIFIER::={ rsRXSysObjects 2}rsRXSysNvs OBJECTIDENTIFIER::={ rsRXSysObjects 3}rsRXSysSlot OBJECTIDENTIFIER::={ rsRXSysObjects 4}rsRXSysPort OBJECTIDENTIFIER::={ rsRXSysObjects 5}rsRXSysPower OBJECTIDENTIFIER::={ rsRXSysObjects 6}rsRXSysTemperature OBJECTIDENTIFIER::={ rsRXSysObjects 7}
rsRXSysSubsystem OBJECTIDENTIFIER::={ rsRXSysObjects 8}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++RsSysCardType ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The type of card in a system slot:
unknown Unknown type.
srp Switch/Route Processor.
ct3 Channelized T3.
oc3 OC-3 (SONET/SDH).
ut3Atm Unchannelized T3 (ATM service).
ut3Frame Unchannelized T3 (Frame service).
ue3Atm Unchannelized E3 (ATM service).
ue3Frame Uncahnnelized E3 (Frame service).
ce1 Channelized E1.
ct1 Channelized T1.
dpfe Dual Port Fast Ethernet.
oc12Pos OC-12 (POS/SDH).
oc12Atm OC-12 (ATM service).
oc3Pos Quad OC-3 (POS/SDH).
oc3Atm Quad OC-3 (ATM service).
ge Gigabit Ethernet.
fe8 Fast Ethernet 8-port.
oc3oc12Pos Generic OC3/OC12 POS (multi-personality).
oc3oc12Atm Generic OC3/OC12 ATM (multi-personality).
coc3oc12 Channelized generic OC3/OC12 (multi-personality)
coc3 Channelized OC3
coc12 Channelized OC12."SYNTAXINTEGER{unknown(0),srp(1),ct3(2),oc3(3),ut3Atm(4),
ut3Frame(5),ue3Atm(6),ue3Frame(7),ce1(8),ct1(9),dpfe(10),oc12Pos(11),oc12Atm(12),oc3Pos(13),oc3Atm(14),ge(15),fe8(16),oc3oc12Pos(17),oc3oc12Atm(18),coc3oc12(19),coc3(20),coc12(21)}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Chassis objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysChassisRev OBJECT-TYPE
SYNTAXInteger32(0..255)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Chassis revision number. If unknown, the value 255 is reported."::={ rsRXSysGeneral 1}rsRXSysSwVersion OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Currently executing operational software version."::={ rsRXSysGeneral 2}rsRXSysSwBuildDate OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Build date of currently executing operational software version."::={ rsRXSysGeneral 3}rsRXSysRevertControl OBJECT-TYPESYNTAXINTEGER{off(0),immediate(1),timeOfDay(2)}MAX-ACCESSread-writeSTATUScurrent
DESCRIPTION"Global revert control:
off Disable global revert.
immediate All slots are to revert immediately (asap).
timeOfDay All slots are to revert at time specified by
rsRxSysRevertTimeOfDay. This object/value must
be set concurrently with rsRXSysRevertTimeOfDay."::={ rsRXSysGeneral 4}rsRXSysRevertTimeOfDay OBJECT-TYPESYNTAXInteger32(0..86399)UNITS"seconds"MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The number of seconds past midnight on any given day at which time
reverts are allowed to occur. This object must be set concurrently
with rsRXSysRevertControl."::={ rsRXSysGeneral 5}rsRXSysBootConfigControl OBJECT-TYPESYNTAXINTEGER{file(0),fileOnce(1),factoryDefaults(2),runningConfiguration(3)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"System boot configuration control:
file Revert to configuration settings specified by
rsRXSysBootConfigFile. The
rsRXSysBootConfigControl and
rsRXSysBootConfigFile must be specified
together in the same set request pdu.
fileOnce Revert to configuration settings specified by
rsRXSysBootConfigFile. Do not continue to
use file after using it once. The
rsRXSysBootConfigControl and
rsRXSysBootConfigFile must be specified
together in the same set request pdu.
factoryDefaults Revert to factory default settings.
runningConfiguration Revert to current settings."::={ rsRXSysGeneral 6}rsRXSysBootBackupConfigControl OBJECT-TYPESYNTAXINTEGER{file(0),factoryDefaults(1),none(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"System boot backup configuration control:
file Revert to backup configuration settings
specified by rsRXSysBootBackupConfigFile.
The rsRXSysBootBackupConfigControl and
rsRXSysBootBackupConfigFile must be specified
together in the same set request pdu.
factoryDefaults Revert to factory default settings.
none Specify no backup."
::={ rsRXSysGeneral 7}rsRXSysBootForceBackupControl OBJECT-TYPESYNTAXINTEGER{off(0),on(1)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"System boot force backup control:
off Do not force revert to backup settings.
on Do force revert to backup settings."::={ rsRXSysGeneral 8}rsRXSysBootAutoRevertControl OBJECT-TYPESYNTAXINTEGER{default(0),never(1),set(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"System boot auto revert control:
default Use default auto-revert tolerances.
never Never auto-revert to backup.
set Set auto-revert settings at specified tolerances."::={ rsRXSysGeneral 9}rsRXSysBootAutoRevertCountTolerance OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-write
STATUScurrentDESCRIPTION"The auto-revert reboot count tolerance."::={ rsRXSysGeneral 10}rsRXSysBootAutoRevertTimeTolerance OBJECT-TYPESYNTAXUnsigned32UNITS"seconds"MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The auto-revert reboot time tolerance."::={ rsRXSysGeneral 11}rsRXSysBootReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local boot release file name, with extension .rel."DEFVAL{""}::={ rsRXSysGeneral 12}rsRXSysBootConfigFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local boot configuration file name, with extension .cnf.
The rsRXSysBootConfigControl and rsRXSysBootConfigFile must
be specified together in the same set request pdu."DEFVAL{""}::={ rsRXSysGeneral 13}rsRXSysBootBackupReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local backup boot release file name, with extension .rel."DEFVAL{""}::={ rsRXSysGeneral 14}rsRXSysBootBackupConfigFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local backup boot configuration file name, with extension .cnf.
The rsRXSysBootBackupConfigControl and rsRXSysBootBackupConfigFile
must be specified together in the same set request pdu."DEFVAL{""}::={ rsRXSysGeneral 15}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Fabric objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
rsRXSysFabricSpeed OBJECT-TYPESYNTAXInteger32UNITS"gigabits per second"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Speed of switching fabric, in gigabits per second."::={ rsRXSysFabric 1}rsRXSysFabricRev OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Fabric revision number. If unknown, the value 255 is reported."::={ rsRXSysFabric 2}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Nvs objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysNvsStatus OBJECT-TYPESYNTAXINTEGER{notPresent(0),writeProtected(1),volumeError(2),nearCapacity(3),ok(4)}MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Status of non-volatile storage (NVS):
notPresent NVS is not installed.
writeProtected NVS is write-protected.
volumeError Status poll of NVS failed.
nearCapacity Utilization exceeds 85% of NVS capacity.
ok NVS is operational, none of the preceding
conditions apply."::={ rsRXSysNvs 1}rsRXSysNvsCapacity OBJECT-TYPESYNTAXInteger32UNITS"megabytes"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Capacity of NVS storage in megabytes."::={ rsRXSysNvs 2}rsRXSysNvsUtilPct OBJECT-TYPESYNTAXInteger32(-1..100)UNITS"percent"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Percentage of NVS storage used.
A value of -1 indicates NVS utilization is unknown."::={ rsRXSysNvs 3}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Slot objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysSlotCount OBJECT-TYPESYNTAXInteger32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of slots in the system."::={ rsRXSysSlot 1}rsRXSysSlotTable OBJECT-TYPESYNTAXSEQUENCEOF RsRXSysSlotEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table of system slots."::={ rsRXSysSlot 2}rsRXSysSlotEntry OBJECT-TYPESYNTAX RsRXSysSlotEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table entry describing contents of a system slot."INDEX{ rsRXSysSlotIndex }::={rsRXSysSlotTable 1}
RsRXSysSlotEntry ::=SEQUENCE{
rsRXSysSlotIndex Integer32,
rsRXSysSlotDescr DisplayString,
rsRXSysSlotCurrentCardType RsSysCardType,
rsRXSysSlotRev Integer32,
rsRXSysSlotAdminStatus RsEnable,
rsRXSysSlotOperStatus INTEGER,
rsRXSysSlotDisableReason INTEGER,
rsRXSysSlotExpectedCardType RsSysCardType,
rsRXSysSlotControl INTEGER,
rsRXSysSlotCpuUtilPct Integer32,
rsRXSysSlotMemUtilPct Integer32,
rsRXSysSlotIoaPresent TruthValue,
rsRXSysSlotPortCount Integer32,
rsRXSysSlotLastChange TimeTicks,
rsRXSysSlotRedundancyLockout RsEnable,
rsRXSysSlotRedundancyGroupId Unsigned32,
rsRXSysSlotSpareServer TruthValue,
rsRXSysSlotAssociatedSlot Integer32,
rsRXSysSlotRevertControl INTEGER,
rsRXSysSlotRedundancyRevertTime DateAndTime,
rsRXSysSlotBootReleaseFile DisplayString,
rsRXSysSlotBootBackupReleaseFile DisplayString,
rsRXSysSlotSerialNumber DisplayString,
rsRXSysSlotAssemblyPartNumber DisplayString,
rsRXSysSlotAssemblyRev DisplayString,
rsRXSysSlotIoaSerialNumber DisplayString,
rsRXSysSlotIoaAssemblyPartNumber DisplayString,
rsRXSysSlotIoaAssemblyRev DisplayString}rsRXSysSlotIndex OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Slot number.
NOTE: Port numbers are zero-based."::={ rsRXSysSlotEntry 1}rsRXSysSlotDescr OBJECT-TYPESYNTAXDisplayString(SIZE(0..63))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Textual description of the card."::={ rsRXSysSlotEntry 2}rsRXSysSlotCurrentCardType OBJECT-TYPESYNTAX RsSysCardType
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Type of card actually in the slot. This could be different from the
type reported in rsRXSysSlotExpectedCardType, in which case it may
be necessary to set rsRXSysSlotControl to 'flush' before this card
can be made operational."::={ rsRXSysSlotEntry 3}rsRXSysSlotRev OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Revision number of the card. If unknown, the value 255 is reported."::={ rsRXSysSlotEntry 4}rsRXSysSlotAdminStatus OBJECT-TYPESYNTAX RsEnable
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Exerts administrative control to enable/disable the slot."::={ rsRXSysSlotEntry 5}rsRXSysSlotOperStatus OBJECT-TYPESYNTAXINTEGER{unknown(0),empty(1),disabled(2),failed(3),booting(4),initializing(5),online(6),standby(7),inactive(8)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Status of the card."::={ rsRXSysSlotEntry 6}rsRXSysSlotDisableReason OBJECT-TYPESYNTAXINTEGER{none(0),unknown(1),
assessing(2),admin(3),cardMismatch(4),fabricLimit(5),imageError(6)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates the condition causing the slot to be disabled:
none Value when card is not disabled.
unknown Unknown reason for disablement.
assessing The slot content is being assessed (transient
initialization state).
admin The slot is administratively disabled.
cardMismatch The current card type conflicts with configuration
associated with a different card type that previously
occupied the slot.
fabricLimit Card resource requirements exceed available fabric
capacity.
imageError Software image for card is missing or invalid."::={ rsRXSysSlotEntry 7}rsRXSysSlotExpectedCardType OBJECT-TYPESYNTAX RsSysCardType
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Type of card associated with this slot through prior presence.
After the card is removed, this association persists (and inhibits
operation of a different card type in this slot, if one is inserted)
until rsRXSysSlotControl is set to 'flush'."
::={ rsRXSysSlotEntry 8}rsRXSysSlotControl OBJECT-TYPESYNTAXINTEGER{noOperation(0),flush(1),reset(2),forceFailover(3),noBoot(4),noBootBackup(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Administrative control of this slot:
noOperation Setting this value has no effect.
flush Flushes configuration associated with a
card type that previously occupied this slot.
Used to explicitly confirm that the slot is
now empty, or contains a different card type.
Card must be disabled when this value is asserted.
See description for rsRXSysSlotDisableReason.
reset Resets the slot.
forceFailover Forces the slot to failover to backup.
noBoot Deconfigure primary release file for the slot.
noBootBackup Deconfigure backup release file for the slot."::={ rsRXSysSlotEntry 9}rsRXSysSlotCpuUtilPct OBJECT-TYPESYNTAXInteger32(-1..100)
UNITS"percent"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Percentage of CPU utilization.
A value of -1 indicates the utilization is unknown."::={ rsRXSysSlotEntry 10}rsRXSysSlotMemUtilPct OBJECT-TYPESYNTAXInteger32(-1..100)UNITS"percent"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Percentage of memory utilization.
A value of -1 indicates the utilization is unknown."::={ rsRXSysSlotEntry 11}rsRXSysSlotIoaPresent OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates whether the card's corresponding I/O adapter
is present."::={ rsRXSysSlotEntry 12}rsRXSysSlotPortCount OBJECT-TYPESYNTAXInteger32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Number of physical ports for the EXPECTED card type for this slot.
NOTE: In event of a card mismatch in this slot, the port count for
the CURRENT card in this slot is not recognized/reported until
the configuration for the EXPECTED card is explicitly flushed via
rsRXSysSlotControl."::={ rsRXSysSlotEntry 13}rsRXSysSlotLastChange OBJECT-TYPESYNTAXTimeTicksMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The value of sysUpTime when the value of rsRXSysSlotOperStatus
last changed."::={ rsRXSysSlotEntry 14}rsRXSysSlotRedundancyLockout OBJECT-TYPESYNTAX RsEnable
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Exerts administrative control to enable/disable Redundancy protection
for the slot."::={ rsRXSysSlotEntry 15}rsRXSysSlotRedundancyGroupId OBJECT-TYPESYNTAXUnsigned32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Identifies the Redundancy group as derived from hardware settings."::={ rsRXSysSlotEntry 16}rsRXSysSlotSpareServer OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"True only if the line card in slot is a spare redundant server."::={ rsRXSysSlotEntry 17}rsRXSysSlotAssociatedSlot OBJECT-TYPESYNTAXInteger32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"If the line card in slot is a spare redundant server, then the
associated slot is the slot of the primary server this server spares
for.
If the line card in slot is a primary redundant server, then the
associated slot is the slot of the spare server that serves as this
slot's backup."::={ rsRXSysSlotEntry 18}rsRXSysSlotRevertControl OBJECT-TYPESYNTAXINTEGER{off(0),immediate(1),timeAndDate(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Per-slot revert control:
off Disable slot revert.
immediate Slot is to revert immediately (asap).
timeAndDate Slot is to revert at time specified by
rsRxSysSlotRedundancyRevertTime."::={ rsRXSysSlotEntry 19}rsRXSysSlotRedundancyRevertTime OBJECT-TYPESYNTAXDateAndTime
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The date and time associated with the timeAndDate (delayed) revert
operation."::={ rsRXSysSlotEntry 20}rsRXSysSlotBootReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local boot release file name for this slot, with extension .rel."DEFVAL{""}::={ rsRXSysSlotEntry 21}rsRXSysSlotBootBackupReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local backup boot release file name for this slot, with extension
.rel."DEFVAL{""}::={ rsRXSysSlotEntry 22}rsRXSysSlotSerialNumber OBJECT-TYPESYNTAXDisplayString(SIZE(0..10))
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The serial number of the card in this slot."DEFVAL{""}::={ rsRXSysSlotEntry 23}rsRXSysSlotAssemblyPartNumber OBJECT-TYPESYNTAXDisplayString(SIZE(0..10))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The part number of the card in this slot."DEFVAL{""}::={ rsRXSysSlotEntry 24}rsRXSysSlotAssemblyRev OBJECT-TYPESYNTAXDisplayString(SIZE(0..3))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The revision number of the card assembly in this slot."DEFVAL{""}::={ rsRXSysSlotEntry 25}rsRXSysSlotIoaSerialNumber OBJECT-TYPE
SYNTAXDisplayString(SIZE(0..10))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The serial number of the I/O adaptor on the card in this slot."DEFVAL{""}::={ rsRXSysSlotEntry 26}rsRXSysSlotIoaAssemblyPartNumber OBJECT-TYPESYNTAXDisplayString(SIZE(0..10))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The part number of the I/O adaptor on the card in this slot."DEFVAL{""}::={ rsRXSysSlotEntry 27}rsRXSysSlotIoaAssemblyRev OBJECT-TYPESYNTAXDisplayString(SIZE(0..3))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The revision number of the I/O adaptor assembly on the card in this
slot."DEFVAL{""}::={ rsRXSysSlotEntry 28}
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- System Port objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysPortTable OBJECT-TYPESYNTAXSEQUENCEOF RsRXSysPortEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table of system physical ports.
The information in this table reflects the ports for the EXPECTED
card type in each slot; in event of a card mismatch, this table
permits navigation of the existing configuration of the expected
card type."::={ rsRXSysPort 1}rsRXSysPortEntry OBJECT-TYPESYNTAX RsRXSysPortEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table entry describing a physical port of the system."INDEX{ rsRXSysSlotIndex, rsRXSysPortIndex }::={rsRXSysPortTable 1}
RsRXSysPortEntry ::=SEQUENCE{
rsRXSysPortIndex Integer32,
rsRXSysPortDescr DisplayString,
rsRXSysPortType INTEGER,
rsRXSysPortIfIndex InterfaceIndexOrZero}rsRXSysPortIndex OBJECT-TYPESYNTAXInteger32(0..255)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Port number of this physical port, relative to the slot in which it
resides. Each physical port is uniquely distinguished by its slot/port
pair.
NOTE: Port numbers are zero-based."::={ rsRXSysPortEntry 1}rsRXSysPortDescr OBJECT-TYPESYNTAXDisplayString(SIZE(0..63))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Textual description of this port."::={ rsRXSysPortEntry 2}rsRXSysPortType OBJECT-TYPESYNTAXINTEGER{unknown(0),eth(1),ct3(2),oc3c(3),ut3Atm(4),ut3Frame(5),ue3Atm(6),
ue3Frame(7),ce1(8),ct1(9),oc12cPos(10),oc12cAtm(11),oc3cPos(12),oc3cAtm(13),coc3(14),coc12(15)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Type of the physical port:
unknown Unknown port type.
eth Ethernet.
ct3 Channelized T3.
oc3c OC-3c (SONET/SDH).
ut3Atm Unchannelized T3 (ATM service).
ut3Frame Unchannelized T3 (Frame service).
ue3Atm Unchannelized E3 (ATM service).
ue3Frame Unchannelized E3 (Frame service).
ce1 Channelized E1.
ct1 Channelized T1.
oc12Pos OC-12 (POS/SDH).
oc12Atm OC-12 (ATM service).
oc3Pos OC-3 (POS/SDH).
oc3Atm OC-3 (ATM service).
coc3 Channelized OC-3.
coc12 Channelized OC-12"::={ rsRXSysPortEntry 3}rsRXSysPortIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-only
STATUScurrentDESCRIPTION"The ifIndex of the Interfaces MIB ifTable entry corresponding to this
physical port; if zero, the ifIndex is unknown or does not exist."::={ rsRXSysPortEntry 4}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- System Power objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysPowerTable OBJECT-TYPESYNTAXSEQUENCEOF RsRXSysPowerEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table of system power elements."::={ rsRXSysPower 1}rsRXSysPowerEntry OBJECT-TYPESYNTAX RsRXSysPowerEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table entry describing status of a system power element."INDEX{ rsRXSysPowerIndex }::={rsRXSysPowerTable 1}
RsRXSysPowerEntry ::=SEQUENCE{
rsRXSysPowerIndex Integer32,
rsRXSysPowerDescr DisplayString,
rsRXSysPowerStatus INTEGER}rsRXSysPowerIndex OBJECT-TYPESYNTAXInteger32(0..255)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Arbitrary integer index to distinguish entries in this table."::={ rsRXSysPowerEntry 1}rsRXSysPowerDescr OBJECT-TYPESYNTAXDisplayString(SIZE(0..63))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Textual description of this power element."::={ rsRXSysPowerEntry 2}rsRXSysPowerStatus OBJECT-TYPESYNTAXINTEGER{inactive(0),active(1)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The status of the power element:
inactive No power available from this element.
active Power available from this element."::={ rsRXSysPowerEntry 3}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- System Temp objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysTempFanStatus OBJECT-TYPESYNTAXINTEGER{failed(0),ok(1)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Status of fan tray."::={ rsRXSysTemperature 1}rsRXSysTempTable OBJECT-TYPESYNTAXSEQUENCEOF RsRXSysTempEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table of system temperature sensors.
Sensors are distributed across the chassis, at least one sensor per
populated slot."::={ rsRXSysTemperature 2}rsRXSysTempEntry OBJECT-TYPESYNTAX RsRXSysTempEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table entry describing status of a temperature sensor."INDEX{ rsRXSysSlotIndex, rsRXSysTempIndex }::={rsRXSysTempTable 1}
RsRXSysTempEntry ::=SEQUENCE{
rsRXSysTempIndex Integer32,
rsRXSysTempDescr DisplayString,
rsRXSysTempStatus INTEGER,
rsRXSysTempValue Integer32}rsRXSysTempIndex OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Arbitrary integer index to distinguish sensors associated with the same
chassis slot."::={ rsRXSysTempEntry 1}rsRXSysTempDescr OBJECT-TYPESYNTAXDisplayString(SIZE(0..63))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Textual description of this sensor."::={ rsRXSysTempEntry 2}rsRXSysTempStatus OBJECT-TYPESYNTAXINTEGER{unknown(0),failed(1),tooLow(2),nominal(3),
tooHigh(4)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The status of a temperature sensor:
unknown Unknown.
failed Failed.
tooLow Below nominal range.
nominal Within nominal range.
tooHigh Above nominal range."::={ rsRXSysTempEntry 3}rsRXSysTempValue OBJECT-TYPESYNTAXInteger32UNITS"degrees Celsius"MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The temperature measured by this sensor in degrees Celsius.
This measurement is valid only if the value of the corresponding
rsRXSysTempStatus is nominal."::={ rsRXSysTempEntry 4}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Subsystem objects
--
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysSubsystemTable OBJECT-TYPESYNTAXSEQUENCEOF RsRXSysSubsystemEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table of subsystems."::={ rsRXSysSubsystem 1}rsRXSysSubsystemEntry OBJECT-TYPESYNTAX RsRXSysSubsystemEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table entry containing information pertaining to a subsystem."INDEX{ rsRXSysSubsystemIndex }::={rsRXSysSubsystemTable 1}
RsRXSysSubsystemEntry ::=SEQUENCE{
rsRXSysSubsystemIndex Integer32,
rsRXSysSubsystemName DisplayString,
rsRXSysSubsystemControl INTEGER,
rsRXSysSubsystemBootReleaseFile DisplayString,
rsRXSysSubsystemBootBackupReleaseFile DisplayString}rsRXSysSubsystemIndex OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Subsystem number."::={ rsRXSysSubsystemEntry 1}rsRXSysSubsystemName OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The name of the subsystem."
::={ rsRXSysSubsystemEntry 2}rsRXSysSubsystemControl OBJECT-TYPESYNTAXINTEGER{noOperation(0),noBoot(1),noBootBackup(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Administrative control of this subsystem:
noOperation Setting this value has no effect.
noBoot Deconfigure primary release file for the subsystem.
noBootBackup Deconfigure backup release file for the subsystem."::={ rsRXSysSubsystemEntry 3}rsRXSysSubsystemBootReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local boot release file name for this subsystem, with extension
.rel."DEFVAL{""}::={ rsRXSysSubsystemEntry 4}rsRXSysSubsystemBootBackupReleaseFile OBJECT-TYPESYNTAXDisplayString(SIZE(0..128))
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The local backup boot release file name for this subsystem, with
extension .rel."DEFVAL{""}::={ rsRXSysSubsystemEntry 5}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Traps & Trap Control
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-- The rsRXSysTrap OBJECT IDENTIFIER is used to define SNMPv2
-- Notifications that are easily translated into SNMPv1 Traps.rsRXSysSlotOperStatusChange NOTIFICATION-TYPEOBJECTS{ rsRXSysSlotCurrentCardType,
rsRXSysSlotAdminStatus,
rsRXSysSlotOperStatus,
rsRXSysSlotDisableReason,
rsRXSysSlotSpareServer,
rsRXSysSlotAssociatedSlot }STATUScurrentDESCRIPTION"Reports a status change for a slot.
This trap is generated on a transition into a stable state
(online or disabled) or on a transition out of online."::={ rsRXSysTrap 1}rsRXSysPowerStatusChange NOTIFICATION-TYPEOBJECTS{ rsRXSysPowerStatus }STATUScurrentDESCRIPTION
"Reports a change in the status of a power element."::={ rsRXSysTrap 2}rsRXSysTempFanStatusChange NOTIFICATION-TYPEOBJECTS{ rsRXSysTempFanStatus }STATUScurrentDESCRIPTION"Reports a change in the status of the fan tray."::={ rsRXSysTrap 3}rsRXSysTempStatusChange NOTIFICATION-TYPEOBJECTS{ rsRXSysTempStatus }STATUScurrentDESCRIPTION"Reports a change in the status of a temperature sensor."::={ rsRXSysTrap 4}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsRXSysCompliances OBJECTIDENTIFIER::={ rsRXSysConformance 1}rsRXSysGroups OBJECTIDENTIFIER::={ rsRXSysConformance 2}-- compliance statementsrsRXSysCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement the Redstone
System MIB."MODULE-- this moduleMANDATORY-GROUPS{ rsRXSysGroup, rsRXSysNotifyGroup }
::={ rsRXSysCompliances 1}-- units of conformancersRXSysGroup OBJECT-GROUPOBJECTS{-- General chassis objects
rsRXSysChassisRev,
rsRXSysSwVersion,
rsRXSysSwBuildDate,
rsRXSysRevertControl,
rsRXSysRevertTimeOfDay,
rsRXSysBootConfigControl,
rsRXSysBootBackupConfigControl,
rsRXSysBootForceBackupControl,
rsRXSysBootAutoRevertControl,
rsRXSysBootAutoRevertCountTolerance,
rsRXSysBootAutoRevertTimeTolerance,
rsRXSysBootReleaseFile,
rsRXSysBootConfigFile,
rsRXSysBootBackupReleaseFile,
rsRXSysBootBackupConfigFile,-- Fabric objects
rsRXSysFabricSpeed,
rsRXSysFabricRev,-- NVS objects
rsRXSysNvsStatus,
rsRXSysNvsCapacity,
rsRXSysNvsUtilPct,-- Slot objects
rsRXSysSlotCount,
rsRXSysSlotDescr,
rsRXSysSlotCurrentCardType,
rsRXSysSlotRev,
rsRXSysSlotAdminStatus,
rsRXSysSlotOperStatus,
rsRXSysSlotDisableReason,
rsRXSysSlotExpectedCardType,
rsRXSysSlotControl,
rsRXSysSlotCpuUtilPct,
rsRXSysSlotMemUtilPct,
rsRXSysSlotIoaPresent,
rsRXSysSlotPortCount,
rsRXSysSlotLastChange,
rsRXSysSlotRedundancyLockout,
rsRXSysSlotRedundancyGroupId,
rsRXSysSlotSpareServer,
rsRXSysSlotAssociatedSlot,
rsRXSysSlotRevertControl,
rsRXSysSlotRedundancyRevertTime,
rsRXSysSlotBootReleaseFile,
rsRXSysSlotBootBackupReleaseFile,
rsRXSysSlotSerialNumber,
rsRXSysSlotAssemblyPartNumber,
rsRXSysSlotAssemblyRev,
rsRXSysSlotIoaSerialNumber,
rsRXSysSlotIoaAssemblyPartNumber,
rsRXSysSlotIoaAssemblyRev,-- Port objects
rsRXSysPortDescr,
rsRXSysPortType,
rsRXSysPortIfIndex,-- Power objects
rsRXSysPowerDescr,
rsRXSysPowerStatus,-- Temperature objects
rsRXSysTempFanStatus,
rsRXSysTempDescr,
rsRXSysTempStatus,
rsRXSysTempValue,-- Subsystem objects
rsRXSysSubsystemName,
rsRXSysSubsystemControl,
rsRXSysSubsystemBootReleaseFile,
rsRXSysSubsystemBootBackupReleaseFile
}STATUScurrentDESCRIPTION"A collection of management objects pertaining to system capabilities in
a Redstone product."::={ rsRXSysGroups 1}rsRXSysNotifyGroup NOTIFICATION-GROUPNOTIFICATIONS{
rsRXSysSlotOperStatusChange,
rsRXSysPowerStatusChange,
rsRXSysTempFanStatusChange,
rsRXSysTempStatusChange
}STATUScurrentDESCRIPTION"A collection of management notifications pertaining to system
operations in a Redstone product."::={ rsRXSysGroups 2}END